International Edition
Latest News
Business

Joint Renewable-Storage Operation: Case Study on Economic Performance, Storage Dynamics, and Market Clearing

Renewable energy generation frequently outstrips grid demand during peak hours, creating complex scheduling challenges for system operators. MDPI reported that a recent technical case study examined the economic and operational performance of a power grid integrating three thermal…

Joint Renewable-Storage Operation: Case Study on Economic Performance, Storage Dynamics, and Market Clearing

Renewable energy generation frequently outstrips grid demand during peak hours, creating complex scheduling challenges for system operators.

MDPI reported that a recent technical case study examined the economic and operational performance of a power grid integrating three thermal units, one hydropower unit, and two joint renewable-storage participants.

The study evaluates a 616-MW wind plant designated as renewable1 and a 160-MW photovoltaic plant designated as renewable2. Each renewable participant features 600 MWh of storage capacity, a maximum charging and discharging power of 100 MW, charging and discharging efficiencies of 95%, and an initial state of charge of 50%, according to MDPI data.

System training data demonstrates rapid financial improvement during early operational rounds before stabilizing. Between training rounds 1 and 200, the reward moving average rises from CNY 2.9457 million to CNY 3.6122 million, while the operating-profit moving average climbs from CNY 3.1126 million to CNY 3.6820 million, MDPI reported.

Following round 200, economic metrics fluctuate around a steady plateau. The operating-profit moving average primarily ranges between CNY 3.5624 million and CNY 3.8216 million, ultimately concluding training at CNY 3.7234 million.

Joint Operation Asset Parameters
Participant Type Renewable Capacity (MW) Storage Energy Capacity (MWh) Max Charging Power (MW)
renewable1 (Wind) 616 600 100
renewable2 (PV) 160 600 100

Intraday market clearing prices fluctuate sharply in response to shifting supply and demand dynamics. At 02:00, the market clearing price drops to 50 CNY/MWh due to low demand and abundant renewable generation, allowing storage systems to absorb surplus energy, MDPI reported.

Conversely, market clearing prices climb to between 1050 and 1062.98 CNY/MWh from 09:15 to 09:30 as load increases and renewable supply falls short of expectations. Hydropower and discharging storage units supply incremental power during these high-cost intervals.

Wind-storage and photovoltaic-storage portfolios display distinct operational profiles throughout the 24-hour cycle. Wind-storage inventory decreases through the morning and midday before recovering via afternoon charging cycles, recording daily charging and discharging totals of 429.41 MWh and 357.28 MWh, respectively, MDPI reported.

Total generator-side final profit reaches CNY 4.4513 million, with the wind-storage portfolio contributing CNY 3.4286 million and hydropower contributing CNY 478,700. Thermal units and photovoltaic portfolios account for the remainder of the settlement distributions under the evaluated framework.

About the author: Business Desk

Business Desk at Archynewsy.