Renda Nova8 Packs Eight 600W GPUs in 4U Liquid-Cooled Server for Air-Cooled Racks

Renda and Nexalus announced a partnership enabling Renda's 4U liquid-cooled server to run eight 600W GPUs at full capacity in air-cooled racks. Data center operators can now deploy liquid-cooled AI hardware within existing 19-inch air-cooled racks, following a…

Renda Nova8 Packs Eight 600W GPUs in 4U Liquid-Cooled Server for Air-Cooled Racks

Renda and Nexalus announced a partnership enabling Renda's 4U liquid-cooled server to run eight 600W GPUs at full capacity in air-cooled racks.

Data center operators can now deploy liquid-cooled AI hardware within existing 19-inch air-cooled racks, following a partnership between Renda and Nexalus announced on Tuesday.

The new Renda Nova8 server integrates eight Nvidia RTX PRO 6000 Blackwell GPUs into a 4U chassis, bypassing the need for facility-wide infrastructure upgrades.

The Nova8 system uses patented jet-impingement cooling technology to maintain thermal control, directing coolant onto plates positioned directly above the hottest sections of the chips. According to AEC Magazine, this bespoke design allows each GPU to occupy a single slot despite the card’s typical dual-slot requirements, enabling all eight units to run at their full 600W capacity within the compact 4U form factor.

Companies claim the system delivers up to 20% greater AI throughput and 22% improved energy efficiency compared to standard air-cooled alternatives, reported morningstar.com. During internal testing, the server achieved 55,000 tokens per second on a Llama 3.3 benchmark.

Renda Nova8 Packs Eight 600W GPUs in 4U Liquid-Cooled Server for Air-Cooled Racks
Photo: morningstar.com

The server design draws on thermal management strategies used in Formula 1 racing, where the companies have previously cooled high-density hardware for eight of the 11 current constructors. As noted by finance.yahoo.com, Ian “8Pack” Parry of Renda stated, “Formula 1 taught us that thermal management decides how much performance you can actually use, and AI is now facing the same challenge at data center scale.”

The system includes redundant cooling features, utilizing 10 pumps and 16 fans to sustain performance. Kenneth O’Mahony, Chief Executive Officer of Nexalus, mentioned to finance.yahoo.com that “Operators need more throughput, but most cannot pause to retrofit their facilities for liquid cooling.”

Renda Nova8 Packs Eight 600W GPUs in 4U Liquid-Cooled Server for Air-Cooled Racks
Photo: finance.yahoo.com

Potential customers can evaluate the hardware through a remote Test Drive program to observe performance on their own specific models. Global after-sales support for the units is managed through a partnership with UNICOM Engineering.

Evaluating Nova8 Performance

Unite.ai notes that while these specifications provide a baseline for assessment, throughput results depend heavily on specific model configurations, input lengths, and precision settings. Buyers are encouraged to determine if power measurements reflect the entire server or specific components before comparing results against existing site requirements.

The companies plan to showcase the Nova8 at Data Centre World Paris on November 18–19, 2026. Qualified organizations can request access to the remote testing platform to validate the hardware against their own production workloads.