Human fingertips perceive pain from millimeter-wave exposure when skin temperature reaches 41.9 °C, a threshold that matches the limit international guidelines already flag as potentially harmful, researchers at Fujita Health University and Nagoya Institute of Technology found. Thirty-five…

Study Identifies 41.9 °C Pain Threshold for Millimeter-Wave Exposure on Human Fingertips

Human fingertips perceive pain from millimeter-wave exposure when skin temperature reaches 41.9 °C, a threshold that matches the limit international guidelines already flag as potentially harmful, researchers at Fujita Health University and Nagoya Institute of Technology found.

Thirty-five healthy adults received a non-contact 28 GHz beam at 1.00 W/cm² on the left middle fingertip for up to ten minutes. Sessions stopped the moment a participant reported pain or when skin temperature hit 44 °C. Eighteen participants (51 %) reached the pain endpoint; seven completed the full exposure without pain. The average pain threshold across those who felt it was 41.9 °C (107.4 °F).

Study Identifies 41.9 °C Pain Threshold for Millimeter-Wave Exposure on Human Fingertips
Photo: pure.nitech.ac.jp

Sensations emerged in a consistent ladder as temperature climbed: warmth, then heat, then tingling, then pain. The tingling stage may give people a few seconds of warning before pain becomes intolerable, the authors noted.

Females were nearly five times more likely than males to report pain (odds ratio 4.80, 95 % CI 1.15–20.09). Logistic regression suggested the gap is partly explained by lower total body water and smaller finger circumference in female participants, factors that concentrate the absorbed energy. The finding implies that a one-size-fits-all approach to safety limits may not be optimal.

These guidelines identify a local skin temperature of 41.9 degrees Celsius as potentially harmful.

Parameter Value
Frequency 28 GHz
Incident power density (1 cm² avg.) 1.00 W/cm²
Input power 8.5 W
Exposure site Left middle fingertip
Maximum exposure time 10 minutes
Safety cut-off temperature 44 °C
Participants 35 healthy adults
Pain threshold (mean) 41.9 °C
Participants reaching pain 18 of 35 (51 %)
Female vs. male pain odds ratio 4.80 (1.15–20.09)

Funding came from a grant from the Ministry of Internal Affairs and Communications. The authors declared no conflicts of interest, financial or otherwise.

Fujita Health University, founded in 1964 by Dr. Keisuke Fujita and chartered as a university in 1968, operates the largest single medical facility in Japan, with 1,376 beds as of 2021. The private university in Toyoake, Aichi, ranked first among private universities in the 2018 Times Higher Education World University Ranking.

The study contributes to the growing body of evidence on the health effects of millimeter-wave exposure. As wireless communication systems keep growing, the need for reliable safety data becomes more important. The findings show why it matters to account for differences between people when setting safety factors for millimeter-wave exposure.